GEMINI
MEMORY LIGHTING CONTROL
OPERATOR'S HANDBOOK

Back to contents
CHAPTER 7
FIRST LINE SERVICING
7.1 INTRODUCTION
The Gemini system is extremely reliable and should give no trouble, provided
the environment is as recommended in section 2.4. In the unlikely event
of a fault, users should not, in general, attempt to repair the equipment
themselves, but should immediately notify their local Rank Strand service
agent. 8efore doing this, however, the user should check for obvious faults
such as lack of mains power and blown fuses. The fuses are detailed in
Table 7.1.
Table 7.1
Fuse |
Rating |
Size |
Console Mains Fuse |
5A HRC |
20mm x 5mm ceramic |
Back-up Mains Fuse, 240V |
2A HRC |
20mm x 5mm ceramic |
Back-up Mains Fuse, 110V |
3.15A HRC |
20mm x 5mm ceramic |
Multiplex Interface Unit, mains fuse |
100mA anti-surge |
20mm x 5mm |
|